TORAGE AND STABILITY
1.The test kit can be stored at temperature 2℃ to 30℃
2.Keep the temperature at 15-30℃ during the test.
3.Keep away from sunlight, moisture and heat.
4.In the sealed pouch to the date of expiration.
5.Patient samples perform best if tested immediately after collection.
Material provided
1.30 Individual sealed pouches, each containing:
■Test device
■Desiccant pouch
2.30 Extraction tubes.
3.One extraction buffer in a dropper bottle (6mL): 0.01M phosphate buffer saline (PBS).
TEST PROCEDURE

1.Tear the aluminum foil bag along the incision, take out the test cassette and place it horizontally.
2. Drop the Whole blood sample(2μL) to the scale using A pipette or supplied straw and drop the sample into the filling hole (A).
3. Add 3 drops (about 120μL) of buffer to test cassette into the filling hole (B).
4. Read results after15 minutes. Do not read results after 30minutes.